<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">grekov</journal-id><journal-title-group><journal-title xml:lang="ru">Вестник хирургии имени И.И. Грекова</journal-title><trans-title-group xml:lang="en"><trans-title>Grekov's Bulletin of Surgery</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0042-4625</issn><issn pub-type="epub">2686-7370</issn><publisher><publisher-name>Federal State Budgetary Educational Institution of Higher Education «Academician I.P. Pavlov First St. Petersburg State Medical University» of the Ministry of Healthcare of the Russion Federation, FSBEI HE I.P.Pavlov SPbSMU MOH Russia</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.24884/0042-4625-2013-172-1-116-119</article-id><article-id custom-type="elpub" pub-id-type="custom">grekov-776</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОБЗОРЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>REVIEWS</subject></subj-group></article-categories><title-group><article-title>ПРОБЛЕМА ВЫБОРА ПЛАСТИЧЕСКОГО МАТЕРИАЛА В РЕКОНСТРУКТИВНОЙ ХИРУРГИИ СЕРДЦА</article-title><trans-title-group xml:lang="en"><trans-title></trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Шихвердиев</surname><given-names>Назим Низамович</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Аверкин</surname><given-names>Игорь Игоревич</given-names></name></name-alternatives><email xlink:type="simple">averkin.igor@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Марченко</surname><given-names>Сергей Павлович</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Дарвиш</surname><given-names>Диана Махмудовна</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Алексанян</surname><given-names>Михаил Генрихович</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Первая клиника хирургии (усовершенствования врачей) им. П. А. Куприянова; Военно-медицинская академия им. С. М. Кирова</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>2013</year></pub-date><pub-date pub-type="epub"><day>16</day><month>01</month><year>2018</year></pub-date><volume>172</volume><issue>1</issue><fpage>116</fpage><lpage>119</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Шихвердиев Н.Н., Аверкин И.И., Марченко С.П., Дарвиш Д.М., Алексанян М.Г., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Шихвердиев Н.Н., Аверкин И.И., Марченко С.П., Дарвиш Д.М., Алексанян М.Г.</copyright-holder><copyright-holder xml:lang="en">Шихвердиев Н.Н., Аверкин И.И., Марченко С.П., Дарвиш Д.М., Алексанян М.Г.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.vestnik-grekova.ru/jour/article/view/776">https://www.vestnik-grekova.ru/jour/article/view/776</self-uri><kwd-group xml:lang="ru"><kwd>пластический материал</kwd><kwd>механические свойства</kwd><kwd>реконструктивная хирургия</kwd><kwd>консервант</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Al Halees Z., Al Shahida M., Al Sanei A., Sallehuddin A. et al. Up to 16 years follow-up of aortic valve reconstruction with pericardium: a stentless readily available cheap valve? // Eur. J. Cardio-thoracic Surg. 2005. Vol. 28. P. 200–205.</mixed-citation><mixed-citation xml:lang="en">Al Halees Z., Al Shahida M., Al Sanei A., Sallehuddin A. et al. Up to 16 years follow-up of aortic valve reconstruction with pericardium: a stentless readily available cheap valve? // Eur. J. Cardio-thoracic Surg. 2005. Vol. 28. P. 200–205.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Breinholt J. P. 3rd., Hawkins J. A., Lambert L. M. et al. A prospective analysis of the immunogenicity of cryopreserved nonvalved allografts used in pediatric heart surgery // Circulation. 2000. Vol. 102, Suppl. 3, № 19. P. 179–182.</mixed-citation><mixed-citation xml:lang="en">Breinholt J. P. 3rd., Hawkins J. A., Lambert L. M. et al. A prospective analysis of the immunogenicity of cryopreserved nonvalved allografts used in pediatric heart surgery // Circulation. 2000. Vol. 102, Suppl. 3, № 19. P. 179–182.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Carpentier A., Lemaigre G., Robert L. et al. Biological factors affecting long-term results of valvular heterografts // J. Thorac. Cardiovasc. Surg. 1969. Vol. 58, № 4. P. 467–483.</mixed-citation><mixed-citation xml:lang="en">Carpentier A., Lemaigre G., Robert L. et al. Biological factors affecting long-term results of valvular heterografts // J. Thorac. Cardiovasc. Surg. 1969. Vol. 58, № 4. P. 467–483.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Duncan A. C., Boughner D. Effect of dynamic glutaraldehyde fixation on the viscoelastic properties of bovine pericardial tissue // Biomaterials. 1998. Vol. 19, № 7–9. P. 777–783.</mixed-citation><mixed-citation xml:lang="en">Duncan A. C., Boughner D. Effect of dynamic glutaraldehyde fixation on the viscoelastic properties of bovine pericardial tissue // Biomaterials. 1998. Vol. 19, № 7–9. P. 777–783.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Eckman M. H., Beshansky J. R., Durand-Zaleski I. et al. Anticoagulation for non-cardiac procedures in patient with prosthetic heart valve: does low risk mean high cost? // JAMA. 1990. Vol. 263. P. 1513–1521.</mixed-citation><mixed-citation xml:lang="en">Eckman M. H., Beshansky J. R., Durand-Zaleski I. et al. Anticoagulation for non-cardiac procedures in patient with prosthetic heart valve: does low risk mean high cost? // JAMA. 1990. Vol. 263. P. 1513–1521.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Garcia Paez J. M., Jorge E., Rocha A. et al. Mechanical effects of increases in the load applied in uniaxial and biaxial tensile testing. Part II. Porcine pericardium // J. Materials Science: Materials in Medicine. 2002. Vol. 13, № 5. P. 477–483.</mixed-citation><mixed-citation xml:lang="en">Garcia Paez J. M., Jorge E., Rocha A. et al. Mechanical effects of increases in the load applied in uniaxial and biaxial tensile testing. Part II. Porcine pericardium // J. Materials Science: Materials in Medicine. 2002. Vol. 13, № 5. P. 477–483.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Haluck R. S., Richenbacher W. E., Myers J. L. et al. Pericardium as a thoracic aortic patch: Glutaraldehyde-fixed and fresh autologous pericardium // J. Surg. Res. 1990. Vol. 48, № 6. P. 611–614.</mixed-citation><mixed-citation xml:lang="en">Haluck R. S., Richenbacher W. E., Myers J. L. et al. Pericardium as a thoracic aortic patch: Glutaraldehyde-fixed and fresh autologous pericardium // J. Surg. Res. 1990. Vol. 48, № 6. P. 611–614.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Harken D. E. Heart valves: ten commandments and still counting // Ann. Thorac Surg. 1989. Vol. 48. Suppl. 3. P. 18–19.</mixed-citation><mixed-citation xml:lang="en">Harken D. E. Heart valves: ten commandments and still counting // Ann. Thorac Surg. 1989. Vol. 48. Suppl. 3. P. 18–19.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Hawkins J. A., Breinholt J. P., Lambert L. M. et al. Class I and class II anti-HLA antibodies after implantation of cryopreserved allograft material in pediatric patients // J. Thorac. Cardiovasc. Surg. 2000. Vol. 119, № 2. P. 324–330.</mixed-citation><mixed-citation xml:lang="en">Hawkins J. A., Breinholt J. P., Lambert L. M. et al. Class I and class II anti-HLA antibodies after implantation of cryopreserved allograft material in pediatric patients // J. Thorac. Cardiovasc. Surg. 2000. Vol. 119, № 2. P. 324–330.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Lee J. M., Boughner D. R. Tissue mechanics of canine pericardium in different test environments. Evidence for time-dependent accommodation, absence of plasticity, and new roles for collagen and elastin // Circ. Res. 1981. Vol. 49, № 2. P. 533–544.</mixed-citation><mixed-citation xml:lang="en">Lee J. M., Boughner D. R. Tissue mechanics of canine pericardium in different test environments. Evidence for time-dependent accommodation, absence of plasticity, and new roles for collagen and elastin // Circ. Res. 1981. Vol. 49, № 2. P. 533–544.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Lee J. M., Boughner D. R. Mechanical properties of human pericardium. Differences in viscoelastic response when compared with canine pericardium // Circ. Res. 1985. Vol. 57, № 3. P. 475–481.</mixed-citation><mixed-citation xml:lang="en">Lee J. M., Boughner D. R. Mechanical properties of human pericardium. Differences in viscoelastic response when compared with canine pericardium // Circ. Res. 1985. Vol. 57, № 3. P. 475–481.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Lee J. M., Boughner D. R., Courtman D. W. The glutaraldehyde-stabilized porcine aortic valve xenograft. II. Effect of fixation with or without pressure on the tensile viscoelastic properties of the leaflet material // J. Biomedical Materials Research. 1984. Vol. 18, № 1. P. 79–98.</mixed-citation><mixed-citation xml:lang="en">Lee J. M., Boughner D. R., Courtman D. W. The glutaraldehyde-stabilized porcine aortic valve xenograft. II. Effect of fixation with or without pressure on the tensile viscoelastic properties of the leaflet material // J. Biomedical Materials Research. 1984. Vol. 18, № 1. P. 79–98.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Lee J. M., Haberer S. A., Boughner D. R. The bovine pericardial xenograft: I. Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium // J. Biomedical Materials Research. 1989. Vol. 23, № 5. P. 457–475.</mixed-citation><mixed-citation xml:lang="en">Lee J. M., Haberer S. A., Boughner D. R. The bovine pericardial xenograft: I. Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium // J. Biomedical Materials Research. 1989. Vol. 23, № 5. P. 457–475.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Lee J. M., Langdon S. E. Thickness measurement of soft tissue biomaterials: A comparison of five methods // J. Biomechanics. 1996. Vol. 29, № 6. P. 829–832.</mixed-citation><mixed-citation xml:lang="en">Lee J. M., Langdon S. E. Thickness measurement of soft tissue biomaterials: A comparison of five methods // J. Biomechanics. 1996. Vol. 29, № 6. P. 829–832.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Lee M. C., Fung Y. C., Shabetai R., LeWinter M. M. Biaxial mechanical properties of human pericardium and canine comparisons // Am. J. Physiol. Heart. Circ. Physiol. 1987. Vol. 253, № 1. P. 75–82.</mixed-citation><mixed-citation xml:lang="en">Lee M. C., Fung Y. C., Shabetai R., LeWinter M. M. Biaxial mechanical properties of human pericardium and canine comparisons // Am. J. Physiol. Heart. Circ. Physiol. 1987. Vol. 253, № 1. P. 75–82.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Lee W. K., Park K. D., Kim Y. H. et al. Improved calcification resistance and biocompatibility of tissue patch grafted with sulfonated PEO or heparin after glutaraldehyde fixation // J. Biomed. Mater. Res. 2001. Vol. 58, № 1. P. 27–35.</mixed-citation><mixed-citation xml:lang="en">Lee W. K., Park K. D., Kim Y. H. et al. Improved calcification resistance and biocompatibility of tissue patch grafted with sulfonated PEO or heparin after glutaraldehyde fixation // J. Biomed. Mater. Res. 2001. Vol. 58, № 1. P. 27–35.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Liao K., Frater R. W.M., LaPietra A. et al. Time-dependent effect of glutaraldehyde on the tendency to calcify of both autografts and xenografts // Ann. Thorac. Surg. 1995. Vol. 60, Suppl. 2. P. 343–347.</mixed-citation><mixed-citation xml:lang="en">Liao K., Frater R. W.M., LaPietra A. et al. Time-dependent effect of glutaraldehyde on the tendency to calcify of both autografts and xenografts // Ann. Thorac. Surg. 1995. Vol. 60, Suppl. 2. P. 343–347.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Marien B. J., Raffetto J. D., Seidman C. S. et al. Bovine pericardium vs dacron for patch angioplasty after carotid endarterectomy: a prospective randomized study // Arch. Surg. 2002. Vol. 137, № 7. P. 785–788.</mixed-citation><mixed-citation xml:lang="en">Marien B. J., Raffetto J. D., Seidman C. S. et al. Bovine pericardium vs dacron for patch angioplasty after carotid endarterectomy: a prospective randomized study // Arch. Surg. 2002. Vol. 137, № 7. P. 785–788.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Rajani B., Mee R. B., Ratliff N. B. Evidence for rejection of homograft cardiac valves in infants // J. Thorac. Cardiovasc. Surg. 1998. Vol. 115, № 1. P. 111–117.</mixed-citation><mixed-citation xml:lang="en">Rajani B., Mee R. B., Ratliff N. B. Evidence for rejection of homograft cardiac valves in infants // J. Thorac. Cardiovasc. Surg. 1998. Vol. 115, № 1. P. 111–117.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Roll S., Müller-Nordhorn J., Keil T. et al. Dacron vs. PTFE as bypass materials in peripheral vascular surgery — systematic review and meta-analysis // BMC Surgery. 2008. Vol. 8, № 22. P. 1–8.</mixed-citation><mixed-citation xml:lang="en">Roll S., Müller-Nordhorn J., Keil T. et al. Dacron vs. PTFE as bypass materials in peripheral vascular surgery — systematic review and meta-analysis // BMC Surgery. 2008. Vol. 8, № 22. P. 1–8.</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Sanchez D. M., Gaitán D. M., León A. F. et al. Fixation of Vascular Grafts With Increased Glutaraldehyde Concentration Enhances Mechanical Properties Without Increasing Calcification // ASAIO J. 2007. Vol. 53. Issue 3. P. 257–262.</mixed-citation><mixed-citation xml:lang="en">Sanchez D. M., Gaitán D. M., León A. F. et al. Fixation of Vascular Grafts With Increased Glutaraldehyde Concentration Enhances Mechanical Properties Without Increasing Calcification // ASAIO J. 2007. Vol. 53. Issue 3. P. 257–262.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Tremblay D., Zigras T., Cartier R. et al. A comparison of mechanical properties of materials used in aortic arch reconstruction // Ann. Thorac. Surg. 2009. Vol. 88. P. 1484–1491.</mixed-citation><mixed-citation xml:lang="en">Tremblay D., Zigras T., Cartier R. et al. A comparison of mechanical properties of materials used in aortic arch reconstruction // Ann. Thorac. Surg. 2009. Vol. 88. P. 1484–1491.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Turrentine M. W., Ruzmetov M., Vijay P. et al. Biological versus mechanical aortic valve replacement in children // Ann. Thorac. Surg. 2001. Vol. 71, Suppl. 5. P. 356–360.</mixed-citation><mixed-citation xml:lang="en">Turrentine M. W., Ruzmetov M., Vijay P. et al. Biological versus mechanical aortic valve replacement in children // Ann. Thorac. Surg. 2001. Vol. 71, Suppl. 5. P. 356–360.</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Vincentelli A., Latrémouille C., Zegdi R. et al. Does glutaraldehyde induce calcification of bioprosthetic tissues? // Ann. Thorac. Surg. 1998. Vol. 66, Suppl. 1, № 6. P. 255–258.</mixed-citation><mixed-citation xml:lang="en">Vincentelli A., Latrémouille C., Zegdi R. et al. Does glutaraldehyde induce calcification of bioprosthetic tissues? // Ann. Thorac. Surg. 1998. Vol. 66, Suppl. 1, № 6. P. 255–258.</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">Vincentelli A. Mechanical Modifications to Human Pericardium after brief Immersion in 0.625% Gluteraldehyde // J. Heart Valve Disease. 1998. Vol. 7, № 1. P. 24–29.</mixed-citation><mixed-citation xml:lang="en">Vincentelli A. Mechanical Modifications to Human Pericardium after brief Immersion in 0.625% Gluteraldehyde // J. Heart Valve Disease. 1998. Vol. 7, № 1. P. 24–29.</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Vincentelli A., Zegdi R., Fabre O. et al. Is 10 Minutes the Optimum Immersion Time in 0.6% Glutaraldehyde for Human Pericardium? // J. Heart Valve Disease. 2000. Vol. 9, № 4. P. 567.</mixed-citation><mixed-citation xml:lang="en">Vincentelli A., Zegdi R., Fabre O. et al. Is 10 Minutes the Optimum Immersion Time in 0.6% Glutaraldehyde for Human Pericardium? // J. Heart Valve Disease. 2000. Vol. 9, № 4. P. 567.</mixed-citation></citation-alternatives></ref><ref id="cit27"><label>27</label><citation-alternatives><mixed-citation xml:lang="ru">Yang C. Tissue Engineering of Human Cardiovascular Patches. 2005. P. 4–8.</mixed-citation><mixed-citation xml:lang="en">Yang C. Tissue Engineering of Human Cardiovascular Patches. 2005. P. 4–8.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
