УЛЬТРАЗВУКОВАЯ ДИССЕКЦИЯ И КОАГУЛЯЦИЯ НАСАДКОЙ «ГАРМОНИК ФОКУС» ПРИ АНАТОМИЧЕСКИХ РЕЗЕКЦИЯХ ЛЁГКОГО

https://doi.org/10.24884/0042-4625-2014-173-1-076-080

Аннотация

The authors aimed to evaluate the efficacy of application of ultrasound dissection technology and coagulation by using «Harmonic Focus» (HF) instrument, while performing anatomical resection of the lung in open thoracic surgery. The method was carried out in serial 20 patients with lung cancer, whom the lung anatomical resection was performed. A long attachment (17 cm) with curved branches was applied. There were 11 lobectomies and 9 pneumoectomies. The application of HF allowed the dissection of pleural adhesions, pulmonary ligament, a separation of roots of the lung elements, lymphatic nodes of roots of the lung and mediastinum, in spite of being very close to vessels. A fatty tissue of the mediastinum was removed quickly and practically without blood. The HF considerably accelerated the process of vessel treatment, especially, while performing the lobectomy. At the same time, the attempts of application of HF instrument for separation of interlobal fissure resulted in not quite satisfactory aerostasis and hemostasis. The duration of the lobectomy was 127±35 minutes at the average and in the case of pneumoectomy, it consisted of 120±45 minutes. An intraoperative hemorrhage was 300±145 ml. A quantity of exudates was 440±280 ml by drainage on the first day. The pleural cavity drainage was used during 3±1 days. The HF instrument, which was applied for ultrasonic dissection and coagulation, was characterized by multifunctionality and simplicity of usage. It was recommended for a wide application in the thoracic surgery for performing the anatomical lung resections by thoracotomy method.

Об авторах

Андрей Леонидович Акопов
Первый Санкт-Петербургский государственный медицинский университет им. акад. И. П. Павлова
Россия


Арулдас Карлсон
Первый Санкт-Петербургский государственный медицинский университет им. акад. И. П. Павлова
Россия


Список литературы

1. Campagnacci R., de Sanctis A., Baldarelli M. et al. Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study // Surg. Endosc. 2007. Vol. 21. P. 1526–1531.

2. Harold K. L., Pollinger H., Matthews B. D. et al. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries // Surg. Endosc. 2003. Vol. 17. P. 1228–1230.

3. Kaseda S., Aoki T., Kitano M. Preliminary experience using harmonic scalpel for lung resection under thoracoscopic guidance // Jpn. Endoscopic Surgery. 1997. Vol. 3. P. 254–258.

4. Molnaґr F.T., Szaґntoґ Z., Laґszloґ T. et al. Cutting lung parenchyma using the harmonic scalpel — an animal experiment // Eur. J. Cardiothorac. Surg. 2004. Vol. 26. P. 1192–1195.

5. Nicastri D. G., Wu M., Yun J., Swanson S. J. Evaluation of efficacy of an ultrasonic scalpel for pulmonary vascular ligation in an animal model // J. Thorac. Cardiovasc. Surg. 2007. Vol. 134. P. 160–164.

6. Yamada S., Yoshino K., Inoue H. New-model ultrasonically activated shears for hemostatic sectioning during video-assisted thoracic surgery // Gen. Thorac. Cardiovasc. Surg. 2007. Vol. 55. P. 518–520.


Рецензия

Для цитирования:


Акопов А.Л., Карлсон А. УЛЬТРАЗВУКОВАЯ ДИССЕКЦИЯ И КОАГУЛЯЦИЯ НАСАДКОЙ «ГАРМОНИК ФОКУС» ПРИ АНАТОМИЧЕСКИХ РЕЗЕКЦИЯХ ЛЁГКОГО. Вестник хирургии имени И.И. Грекова. 2014;173(1):076-080. https://doi.org/10.24884/0042-4625-2014-173-1-076-080

For citation:


Akopov A.L., Karlson A. ULTRASONIC DISSECTION AND COAGULATION BY ATTACHMENT «HARMONIC FOCUS» IN ANATOMIC RESECTION OF THE LUNG. Grekov's Bulletin of Surgery. 2014;173(1):076-080. (In Russ.) https://doi.org/10.24884/0042-4625-2014-173-1-076-080

Просмотров: 377


Creative Commons License
Контент доступен под лицензией Creative Commons Attribution 4.0 License.


ISSN 0042-4625 (Print)
ISSN 2686-7370 (Online)