Preview

Вестник хирургии имени И.И. Грекова

Расширенный поиск

ЭФФЕКТИВНОСТЬ РАЗЛИЧНЫХ ФОРМ МЕСТНЫХ ГЕМОСТАТИЧЕСКИХ МАТЕРИАЛОВ НА ОСНОВЕ ОКИСЛЕННОЙ ЦЕЛЛЮЛОЗЫ В ЭКСПЕРИМЕНТЕ

https://doi.org/10.24884/0042-4625-2015-174-6-56-59

Полный текст:

Аннотация

The bleeding of intraoperative period is one of the actual problem in surgery. There aren’t any universal hemostatic means in spite of large variety of modern hemostatic methods. An experimental research studied the results of hemostatic activity of different forms of materials on the basis of oxidize cellulose (a gauze, a powder) as compared with their foreign analog (a hemostatic gauze «Surgicel»). Median of hemostasis time consisted of (120±59,9) and (73±46,8) s, in case of application of gauze and powder preparations, respectively. The rate of group using the hemostatic gauze «Surgicel» was (142±77,4) s. The authors made a conclusion on the basis of given research, that the hemostatic material based on oxidize cellulose (the powder form) showed a more expressed hemostatic activity and reliably twice reduced the time of hemostasis as compared with their analog forms of gauze (p<0,05).

Об авторах

А. Р. Таркова
Новосибирский научно-исследовательский институт патологии кровообращения им. акад. Е. Н. Мешалкина
Россия


А. М. Чернявский
Новосибирский научно-исследовательский институт патологии кровообращения им. акад. Е. Н. Мешалкина
Россия


И. А. Григорьев
Новосибирский научно-исследовательский институт патологии кровообращения им. акад. Е. Н. Мешалкина
Россия


С. В. Морозов
Новосибирский институт органической химии им. Н. Н. Ворожцова
Россия


В. И. Родионов
Новосибирский институт органической химии им. Н. Н. Ворожцова
Россия


Н. И. Кравченко
Новосибирский научно-исследовательский институт патологии кровообращения им. акад. Е. Н. Мешалкина
Россия


Список литературы

1. Качмазов А. А., Жернов А. А. Методы гемостаза и применение препаратов из окисленной восстановленной целлюлозы при резекции почки // Экспер. и клин. урол. 2010. № 4. С. 68-71.

2. Первушин Ю. В., Рогова С. Ш., Ковалевич Н. И. и др. Лабораторные методы исследования системы гемостаза и диагностика нарушений гемокоагуляции. Ставрополь, М.: Москва, 2009. С. 61.

3. Чернявский А. М., Григорьев И. А., Морозов С. В. и др. Контроль локального гемостаза с помощью препаратов окисленной целлюлозы // Хирургия. 2014. № 8. С. 71-75.

4. Agarwal M. M., Mandal A. K., Agarwal S. et al. Surgicel granuloma: unusual cause of «recurrent» mass lesion after laparoscopic nephron-sparing surgery for renal cell carcinoma // Urology. 2010. Vol. 76, № 2. P. 334-335.

5. Al-Shaikh S., Muddaiah A., Lee R. J. et al. Oxidised cellulose powder for haemostasis following sinus surgery: a pilot randomised trial // J. Laryngology & Otology. 2014. Vol. 128, № 8. P. 709-713.

6. Bang B. W., Maeng, J. H., Kim, M. K. et al. Hemostatic action of EGF-endospray on mucosectomy-induced ulcer bleeding animal models // Bio-medical materials and engineering. 2015. Vol. 25, № 1. P. 101-109.

7. Behbehani S., Tulandi T. Oxidized regenerated cellulose imitating pelvic abscess // Obst. Gynecol. 2013. Vol. 121. P. 447-449.

8. Bochicchio G. V., Gupta N., Porte R. J. et al. The finish-3 trial: a phase 3, international, randomized, single-blind, controlled trial of topical fibrocaps in intraoperative surgical hemostasis // J. Amer. Coll. Surg. 2015. Vol. 220, № 1. P. 70-81.

9. Christensen M. C., Dziewior F., Kempel A. et al. Increased chest tube drainage is independently associated with adverse outcome after cardiac surgery // J. Cardiothorac. Vasc. Anesthesia. 2012. Vol. 26, № 1. P. 46-51.

10. Christensen M. C., Krapf S., Kempel A. et al. Costs of excessive postoperative hemorrhage in cardiac surgery // J. Thorac. Cardiovasc. Surg. 2009. Vol. 138, № 3. P. 687-693.

11. Domb A. J., Kost J., Wiseman D. M. Oxidized cellulose: chemistry, processing and medical applications. Handbook of biodegradable polymers. Amsterdam: Harwood Acad. Publ., 1997. P. 291-306.

12. Glance L. G., Dick A. W., Mukamel D. B. et al. Association between intraoperative blood transfusion and mortality and morbidity in patients undergoing noncardiac surgery // Surv. Anesthesiol. 2011. Vol. 55, № 6. P. 288-289.

13. Görlinger K., Shore-Lesserson L., Dirkmann D. et al. Management of hemorrhage in cardiothoracic surgery // J. Cardiothorac. Vasc. Anesthes. 2013. Vol. 27, № 4. P. 20-34.

14. Lewis K. M., Atlee H., Mannone A. et al. Efficacy of hemostatic matrix and microporous polysaccharide hemospheres // J. Surg. Res. 2015. Vol. 193, № 2. P. 825-830.

15. Stokes M. E., Ye X., Shah M. et al. Impact of bleeding-related complications and/or blood product transfusions on hospital costs in inpatient surgical patients // BMC health services research. 2011. Vol. 11, № 1. P. 135.

16. Tam T., Harkins G., Dykes. et al. Oxidized regenerated cellulose resembling vaginal cuff abscess // J. Soc. Laparoendoscop. Surg. 2014. Vol. 18, № 2. P. 353.

17. Tefik T., Sanli O., Oktar et al. Oxidized regenerated cellulose granuloma mimicking recurrent mass lesion after laparoscopic nephron sparing surgery // Int. J. Surg. case reports. 2012. Vol. 3, № 6. P. 227-230.

18. Tschan C. A., Nie M., Schwandt E. et al. Safety and efficacy of micro porous polysaccharide hemospheres in neurosurgery // Neuro surgery. 2011. Vol. 69. P. 49-63.

19. Valentine R., Athanasiadis T., Moratti S. et al. The efficacy of a novel chitosan gel on hemostasis and wound healing after endoscopic sinus surgery // Am. J. Rhinol. Fllergy. 2010. Vol. 24, № 1. P. 70-75.

20. Yau A. H. L., Ou G., Galorport C. et al. Safety and efficacy of Hemo spray® in upper gastrointestinal bleeding // Can. J. Gastr. Hepatol. 2014. Vol. 28, № 2. P. 72.

21. Zimnitsky D. S., Yurkshtovich T. L., Bychkovsky P. M. Synthesis and characterization of oxidized cellulose // J. Polymer Sci. Part A: Polymer Chemistry. 2004. Vol. 42, № 19. P. 4785-4791.


Для цитирования:


Таркова А.Р., Чернявский А.М., Григорьев И.А., Морозов С.В., Родионов В.И., Кравченко Н.И. ЭФФЕКТИВНОСТЬ РАЗЛИЧНЫХ ФОРМ МЕСТНЫХ ГЕМОСТАТИЧЕСКИХ МАТЕРИАЛОВ НА ОСНОВЕ ОКИСЛЕННОЙ ЦЕЛЛЮЛОЗЫ В ЭКСПЕРИМЕНТЕ. Вестник хирургии имени И.И. Грекова. 2015;174(6):56-59. https://doi.org/10.24884/0042-4625-2015-174-6-56-59

For citation:


Tarkova A.R., Chernyavskiy A.M., Grigor’Ev I.A., Morozov S.V., Rodionov V.I., Kravchenko N.I. EFFICACY OF DIFFERENT FORMS OF LOCAL HEMOSTATIC MATERIALS BASED ON OXIDIZE CELLULOSE IN THE EXPERIMENT. Grekov's Bulletin of Surgery. 2015;174(6):56-59. (In Russ.) https://doi.org/10.24884/0042-4625-2015-174-6-56-59

Просмотров: 38


Creative Commons License
Контент доступен под лицензией Creative Commons Attribution 4.0 License.


ISSN 0042-4625 (Print)
ISSN 2686-7370 (Online)